5 8
E L E CT R I C AL CONNE CT I ON
W I NT E R 2 01 5
Make
ABB PVI-3.0-TL-OUTD
ABB 3.6-TL-OUTD
ABB 4.2-TL-OUTD
Bosch BPT-S 3
Bosch BPT-S 3.68
Bosch BPT-S 4
Bosch BPT-S 4.6
Fronius IG TL 3.6
Fronius IG TL 4.0
Fronius IG TL 4.6
Fronius IG TL 5.0
Eversol TL 2000
Eversol TL 3000
Max
DC power
3.2kW 3.9kW 4.2kW 4.8kW 3.85kW 4.19kW 4.82kW 5.25kW 3.08kW 4.48kW
Rated
DC power
input
3.12kW 3.75kW 4.375kW
2.2kW 3.2 kW
Max
DC input
voltage
600V 600V 600V 750V 750V 750V 750V
500V 500V
Nominal
DC input
voltage
360
360V 360V
Max MPP
DC voltage
600V 600V 600V 600V
Max MPP
DC input
power
MPP
DC voltage
range
160V -
530V
120V -
530V
140V -
530V
170V -
600V
170V -
600V
170V -
600V
170V -
600V
350V -
700V
350V -
700V
350V -
700V
350V -
700V
90V -
450V
90V -
450V
Max
DC MPPT
input
current
10A 16A 16A
10.8A 11.8A 13.5A 14.7A 12A 18A
Max
DC MPPT
input
power
2kW 3kW 3kW
Min/Start
DC input
voltage
200V 200V 200V 125V/
170V
125V/
170V
125V/
170V
125V/
170V
350V 350V 350V 350V 80V 80V
Number
of MPPTs
2x
2x
2x
1x
1x
2x
2x
1x
1x
Min MPP
voltage
270V 330V 180V 180V
AC voltage
range
180V -
264V
180V -
264V
180V -
264V
184V -
265V
184V -
265V
184V -
265V
184V -
265V
180V -
270V
180V -
270V
180V -
270V
180V -
270V
180V -
280V
180V -
280V
Max
AC output
current
14.5 A 17.2 A 20A 13A 16A 17.4A 20A 16A 17.4A 20A 21.7A 11A
16A
AC Power
rating
3kW 3.6kW 4.2kW 3kW 3.68kW 4.0kW 4.6kW 3.68kW 4kW 4.6kW 5kW 2kW 3kW
AC Power
rating kVA
Frequency
range
47 - 53Hz 47 - 53Hz 47 - 53Hz 45 - 55Hz 45 - 55Hz 45 - 55Hz 45 - 55Hz
45-55Hz 45-55Hz
Power
factor
0.9 lead-
0.9 lag
0.9 lead-
0.9 lag
0.9 lead-
0.9 lag
0.9 lead-
0.9 lag
0.9 lead-
0.9 lag
0.9 lead-
0.9 lag
0.9 lead-
0.9 lag
1
1
1
1
1
1
Distortion <3.5% <3.5% <3.5% <4.5% <4.5% <4.5% <4.5% <3% <3% <3% <3% <3% <3%
Max
efficiency
96.8% 96.8% 96.8% 97% 97% 97% 97% 97.7% 97.7% 97.7% 97.7% 97% 97%
EU
efficiency
96% 96% 96% 96.2% 96.3% 96.5% 96.5% 97.2% 97.3% 97.3% 97.3% 96.5% 96.5%
All information in this table was sourced frommanufacturers’ sell sheets.