Previous Page  60 / 116 Next Page
Information
Show Menu
Previous Page 60 / 116 Next Page
Page Background

6 0

E L E CT R I C AL CONNE CT I ON

W I NT E R 2 01 5

Make

Schneider RL 3000 E

Schneider RL 4000 E

Schneider RL 5000 E

SolarEdge SE3000

SolarEdge SE3500

SolarEdge SE4000

SolarEdge SE5000

Sunways NT2600

Sunways NT4000

Sunways NT5000

SolarRiver 3000 TL

SolarRiver 3300 TL

SolarRiver 4400 TL

SolarRiver 5200 TL

Max

DC power

3.2kW 4.2kW 5.3kW 3.75kW 4.35kW 5kW 6.25kW

3kW 3.48kW 4.58kW 5.2kW

Rated

DC power

input

2.6kW 3.8kW 4.3kW

Max

DC input

voltage

550V 550V 550V 500V 500V 500V 500V 850V 850V 850V 550V 550V 550V 550V

Nominal

DC input

voltage

350V 350V 350V 350V

380V 380V 380V 380V

Max MPP

DC voltage

Max MPP

DC input

power

3.2kW 3.2kW 3.5kW

MPP

DC voltage

range

160V -

500V

180V -

500V

180V -

500V

350V -

750V

350V -

750V

350V -

750V

200V -

500V

200V -

500V

200V -

500V

200V -

500V

Max

DC MPPT

input

current

10A 12A

18A 11.5A 13.5A 15.5A 19.5A 7.5A 11A 13A 13.5A 17.5A 21A 26A

Max

DC MPPT

input

power

Min/Start

DC input

voltage

100V 100V 100V

100V/

150V

100V/

150V

100V/

150V

100V/

150V

Number

of MPPTs

2x

2x

2x

1x

1x

1x

1x

1x

1x

1x

Min MPP

voltage

AC voltage

range

184V -

276V

184V -

276V

184V -

276V

184V -

268.5V

184V -

268.5V

184V -

268.5V

184V -

268.5V

184V -

265V

184V -

265V

184V -

265V

180V -

270V

180V -

270V

180V -

270V

180V -

270V

Max

AC output

current

13.9A 18.2A 23.2A 16.5A 19.5A 22A 27A 13.6A 16.1A 18.3A 13.8A 16A 22A 24A

AC Power

rating

2.5kW 3.7kW 4.2kW 2.6kW 3kW 4kW 4.6kW

AC Power

rating kVA

3kVA 4kVA 5kVA

2.8kVA 3.3kVA 4.4kVA 5kVA

Frequency

range

45-55Hz 45-55Hz 45-55Hz 45-55Hz 45-55Hz 45-55Hz 45-55Hz

44-

55Hz

44-

55Hz

44-

55Hz

44-

55Hz

Power

factor

0.8 lead-

0.8 lag

0.8 lead-

0.8 lag

0.8 lead-

0.8 lag

1

1

1

1

1

1

1

Distortion <3% <3% <3%

<3% <3% <3%

Max

efficiency

97.5% 97.5% 97.5% 97.6% 97.6% 97.6% 97.6% 97.4% 97.5% 97.5% 97% 97.4% 97.6% 97.6%

EU

efficiency

97% 97% 97% 97.5% 97.5% 97.5% 97.5% 97.1% 97.1% 97.1% 96.3% 96.5% 97.1% 96.8%

All information in this table was sourced frommanufacturers’ sell sheets.